Frank Stem
C R C Critical Reviews in Solid State Sciences
A new general method for measuring the dissolution kinetics of thin films is described. In this technique, the film is cast on a piezoelectric quartz crystal. The mass of the dissolving film is determined as a function of time by monitoring the characteristic oscillation frequency of the crystal. Frequency shifts exhibited by the crystal are shown to be linearly related to the mass of the cast film. The method allows determination of the dissolution kinetics of films knowing only their density and the characteristic oscillation frequency of the uncoated quartz crystal. The technique has several advantages over alternative in situ methods based on optical interferometry or capacitance. It can be used to measure very high dissolution rates and to study thick or opaque films that otherwise could not be studied. © 1986, The Electrochemical Society, Inc. All rights reserved.
Frank Stem
C R C Critical Reviews in Solid State Sciences
G. Will, N. Masciocchi, et al.
Zeitschrift fur Kristallographie - New Crystal Structures
H.D. Dulman, R.H. Pantell, et al.
Physical Review B
B.A. Hutchins, T.N. Rhodin, et al.
Surface Science